To the Editor,

In the majority of coronavirus disease 2019 (COVID-19) patients, respiratory mechanics is different from the “normal” acute respiratory distress syndrome (ARDS) patient. Plateau pressures and driving pressures are often low and respiratory system compliance relatively normal compared to the ARDS patient [1]. Many physicians use high positive end-expiratory pressure (PEEP) for patients with COVID-19 although the potential for recruitment is often low [1, 2]. We fear that the high compliance of the respiratory system in combination with high PEEP will lead to hyperinflation, high dead space, and potentially right ventricular failure.

We have used the following strategy for COVID-19 patients (N = 70): after intubation, immediately prone positioning for at least 3 days, using the lowest possible PEEP to obtain adequate oxygenation with FiO2 of 50%. We assessed the effects of different PEEP levels on respiratory mechanics and ventilation-perfusion mismatching.

Methods

Respiratory mechanics was assessed in COVID-19 patients admitted to the Radboud University Nijmegen Medical Center as part of standard patient care. Brief occlusions were performed to assess end-inspiratory and end-expiratory airway and transpulmonary pressures (absolute and elastance ratio method) and to calculate respiratory and lung compliances as previously described [3, 4]. Dead space ventilation was assessed using two methods:

  1. 1)

    The Bohr equation using partial pressure of carbon dioxide in alveolar air (PACO2) and mixed expired air (PeCO2): (PACO2 − PeCO2)/PACO2. See our previous work for detailed description [5].

  2. 2)

    The Enghoff modification of Bohr’s equation using partial pressure of carbon dioxide in arterial blood (PaCO2): (PaCO2 − PeCO2)/PaCO2. Therefore, shunt and diffusion limitations are taken into the equation.

Results

Advanced respiratory mechanics was assessed in 14 patients (8 males and 6 females, age (mean ± SEM) 67 ± 2 years, body mass index 28.0 ± 0.9 kg/m2) between the 19th of March and 2nd of April (Table 1). Compliance of the respiratory system was low (42 ± 3 mL/cmH2O) due to a lower than normal lung compliance (61 ± 5 mL/cmH2O). However, compared to ARDS patients, lung compliance was relatively high, resulting in low end-inspiratory transpulmonary pressures (12 ± 1 cmH2O). Chest wall compliance was slightly lower than normal due to prone positioning in most patients. COVID-19 patients had high dead space ventilation and gas exchange impairment (Bohr 52 ± 3%; Enghoff modification 67 ± 2%).

Table 1 Respiratory mechanics

Reducing PEEP resulted in an increase in lung compliance and decrease in dead space ventilation, except for patient 1 (Fig. 1).

Fig. 1
figure 1

The effects of increasing positive end-expiratory pressure (PEEP) on lung compliance (N = 9) and dead space ventilation (N = 9). Every patient is depicted with a different symbol and color. a Lung compliance decreased with increasing PEEP levels in 8 patients. b Dead space ventilation according to Bohr increased in all patients with increasing PEEP levels. c In response to higher PEEP levels, dead space ventilation according to Enghoff modification (global gas exchange impairment) increased in 3 patients, first decreased and then increased in 3 patients, decreased in 2 patients, and had no effect in 1 patient

Discussion

We demonstrate that mechanically ventilated patients with COVID-19 have a relatively high lung compliance, high dead space ventilation, and gas exchange impairment. In almost all patients, lung compliance decreased and dead space ventilation increased with increasing PEEP levels.

The decrease in lung compliance and increase in dead space ventilation in response to higher PEEP levels indicate that COVID-19 lesions were not recruited and that higher PEEP levels cause hyperinflation of the more compliant parts of the lung [1]. These results are in accordance with recent findings in COVID-19 patients [2].

When lung compliance increases in response to higher PEEP levels (patient 1), recruitment is likely and PEEP should be set accordingly [1, 2].

All patients responded extremely well to prone positioning, although the exact mechanism is unclear. Redistribution of blood flow seems to be an important mechanism.

In conclusion, we show that higher PEEP levels decrease lung compliance and in most cases increase dead space ventilation, indicating that high PEEP levels probably cause hyperinflation in patients with COVID-19. We suggest using prone position for an extended period of time (e.g., 3–5 days) and apply lower PEEP levels as much as possible.

Availability of data and materials

The datasets used and analyzed during the current study are available from the corresponding author on reasonable request.

Abbreviations

ARDS:

Acute respiratory distress syndrome

COVID-19:

Coronary virus disease 2019

PACO2 :

Partial pressure of carbon dioxide in alveolar air

PaCO2 :

Partial pressure of carbon dioxide in arterial blood

PeCO2 :

Partial pressure of carbon dioxide in mixed expired air

PEEP:

Positive end-expiratory pressure

SEM:

Standard error of the mean

References

  1. Gattinoni L, Chiumello D, Caironi P, Busana M, Romitti F, Brazzi L, et al. COVID-19 pneumonia: different respiratory treatments for different phenotypes? Intensive Care Med. 2020. Epub ahead of print.

  2. Pan C, Chen L, Lu C, Zhang W, Xia JA, Sklar MC, et al. Lung Recruitability in SARS-CoV-2 associated acute respiratory distress syndrome: a single-center, observational study. Am J Respir Crit Care Med. 2020. Epub ahead of print.

  3. Akoumianaki E, Maggiore SM, Valenza F, Bellani G, Jubran A, Loring SH, et al. The application of esophageal pressure measurement in patients with respiratory failure. Am J Respir Crit Care Med. 2014;189(5):520–31.

    Article  Google Scholar 

  4. Yoshida T, Amato MBP, Grieco DL, Chen L, Lima CAS, Roldan R, et al. Esophageal manometry and regional transpulmonary pressure in lung injury. Am J Respir Crit Care Med. 2018;197(8):1018–26.

    Article  Google Scholar 

  5. Doorduin J, Nollet JL, Vugts MP, Roesthuis LH, Akankan F, van der Hoeven JG, et al. Assessment of dead-space ventilation in patients with acute respiratory distress syndrome: a prospective observational study. Crit Care. 2016;20(1):121.

    Article  Google Scholar 

Download references

Acknowledgements

Not applicable.

Funding

There was no financial funding.

Author information

Authors and Affiliations

Authors

Contributions

Data acquisition: LR. Data analysis: LR. Data interpretation: all authors. Manuscript drafting and revising: all authors. The authors read and approved the final manuscript.

Corresponding author

Correspondence to Lisanne Roesthuis.

Ethics declarations

Ethics approval and consent to participate

Due to standard patient care and the urgent need to gain knowledge about this new lung disease, informed consent was deemed unnecessary, but also not feasible in most cases.

Consent for publication

Not applicable.

Competing interests

The authors declare that they have no competing interests.

Additional information

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Roesthuis, L., van den Berg, M. & van der Hoeven, H. Advanced respiratory monitoring in COVID-19 patients: use less PEEP!. Crit Care 24, 230 (2020). https://doi.org/10.1186/s13054-020-02953-z

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/s13054-020-02953-z

Keywords