Article

Recommending Suitable Smart Technology Applications to Support Mobile Healthcare after the COVID-19 Pandemic Using a Fuzzy Approach

1
Department of Industrial Engineering and Management, National Yang Ming Chiao Tung University, University Road, Hsinchu 1001, Taiwan
2
Department of Aeronautical Engineering, Chaoyang University of Technology, Taichung 41349, Taiwan
*
Author to whom correspondence should be addressed.
Healthcare 2021, 9(11), 1461; https://doi.org/10.3390/healthcare9111461
Submission received: 16 September 2021 / Revised: 22 October 2021 / Accepted: 26 October 2021 / Published: 28 October 2021

Abstract

:
The COVID-19 pandemic seems to be entering its final stage. However, to restore normal life, the applications of smart technologies are still necessary. Therefore, this research is dedicated to exploring the applications of smart technologies that can support mobile healthcare after the COVID-19 pandemic. To this end, this study compares smart technology applications to support mobile healthcare within the COVID-19 pandemic with those before the pandemic, so as to estimate possible developments in this field. In addition, to quantitatively assess and compare smart technology applications that may support mobile healthcare after the COVID-19 pandemic, the calibrated fuzzy geometric mean (CFGM)-fuzzy technique for order preference by similarity to ideal solution (FTOPSIS) approach is applied. The proposed methodology has been applied to evaluate and compare nine potential smart technology applications for supporting mobile healthcare after the COVID-19 pandemic. According to the experimental results, “vaccine passport and related applications” and “smart watches” were the most suitable smart technology applications for supporting mobile healthcare after the COVID-19 pandemic.

1. Introduction

Smart technologies are applications of electronic devices or systems that can be connected to the Internet, used interactively, and are to some extent intelligent [1,2,3]. Smart technologies have been widely applied to mobile healthcare before the outbreak of the COVID-19 pandemic [4,5,6,7]. After the outbreak of the COVID-19 pandemic, a number of new smart technology applications have emerged. For example,
  • Robots (or drones) help to build a communication with or send medicine to, a quarantined patient to reduce the burden on medical professionals and contain the contagion [8]. Robots (or drones) are also used to patrol in public spaces, observe and broadcast information to crowds, and monitor traffic more efficiently [9].
  • In factories, voice commands or gestures are used to interact with machines to avoid spreading COVID-19 by touching the machines [10,11]. The same purpose can be achieved by using a smartphone to remotely control a machine [12].
  • Workers wear smart wristbands or watches to detect their body temperature [13].
  • In hotels, autonomous robots emit concentrated UV-C ultraviolet light to disinfect room keys, guest rooms, lobbies, gyms, and other public areas [14].
  • In museums, wearable sensors are used to measure the proximity of visitors to ensure physical distance [15].
  • App-based location-based services disperse users to avoid gatherings [16].
Obviously, smart technology applications to support mobile healthcare during the COVID-19 are different from those used before the pandemic. Some smart technologies (such as robots) are more commonly used, while others (such as apps that recommend restaurants with healthy diets) have lost public attention. With the increasing popularity of vaccination, many countries or regions are gradually unblocking. The COVID-19 pandemic seems to be entering its final stage. However, the impact caused by the COVID-19 pandemic will not disappear in a short time [17]. For the restoration of normal life, the applications of smart technologies are still necessary [18]. Therefore, this study intends to explore what kinds of smart technologies will be commonly applied to support mobile healthcare in the later stages of the pandemic.
The importance and contribution of this study is explained as follows. Suitable smart technology applications to mobile healthcare will change after the COVID-19 pandemic. In theory, some recent studies have found that the acceptance of smart technologies, such as smart robots, electronic medical records (evolved into vaccine passports), smart bracelets, and sociometric badges has become higher during the COVID-19 pandemic [19,20,21,22,23,24,25,26,27]. In contrast, some smart technologies, such as wireless medical sensor networks have been found to be impractical due to the inability to process a large amount of COVID-19 patient data [26]. In other words, after the COVID-19 pandemic, suitable smart technology applications to mobile healthcare will be different from those before the pandemic. This topic has not been thoroughly discussed in the literature. The present study aims to fill this gap. Practically speaking, many mobile healthcare providers are optimistic that the market size of smart technology applications will grow substantially, especially at the front end (client side) of mobile healthcare [28]. However, without distinguishing the changes in the acceptances of different smart technologies during the pandemic, their investments will be blind and not necessarily rewarding [29]. To these mobile healthcare providers, the findings of this study will be of reference value.
The procedure for this study is as follows. First of all, this study analyzes smart technology applications to support mobile healthcare within the COVID-19 pandemic and compares with those before the pandemic. Based on the comparison results, possible developments in the applications of smart technologies to support mobile healthcare in the later stages of the COVID-19 pandemic are estimated. However, the above discussion is qualitative and imprecise. A quantitative analysis is still necessary. To this end, from related literature and reports, some possible smart technology applications are listed and compared using a fuzzy multi-objective decision-making (MCDM) approach—the calibrated fuzzy geometric mean (CFGM) and fuzzy technique for order preference by similarity to ideal solution (FTOPSIS) approach [30], so as to recommend smart technology applications that are more suitable for supporting mobile healthcare in the later stage of the pandemic. In the literature, fuzzy methods or systems have been applied to choose a suitable recovery plan for an ecotourism center [31], choose suitable lockdown relaxation protocols for a government [32], identify and compare risk factors for the spread of COVID-19 [33], classify countries based on their confirmed, recovered, and deaths cases [34], cluster countries according to the spread rates of COVID-19 in these countries [35], etc. These applications are subject to similar problems: the inaccuracy of data, the divergence of subjective opinions, unknown suitability of existing analysis methods, etc.
The contribution of this study is described as follows. Prior to the COVID-19 pandemic, smart technologies have been widely applied to mobile health care [36]. It will be the same after the pandemic is over. This study does not claim that this trend will change but aims to compare whether the widely used smart technologies are different before and after the COVID-19 pandemic. For this reason, this research applies a fuzzy method to analyze the collected data. The contribution of this research lies in the comparison of the characteristics of smart technologies applied to mobile health care before and after the pandemic. The fuzzy method applied in this study is just a data analysis tool. Other analysis methods, such as stochastic methods, are also applicable.
The rest of this paper is organized as follows. Section 2 analyzes smart technology applications to support mobile healthcare within the COVID-19 pandemic and compares them with those before the pandemic. Based on the comparison results, possible developments in smart technology applications to support mobile healthcare in the later stages of the COVID-19 pandemic are estimated. Section 3 introduces the CFGM-FTOPSIS approach for assessing and comparing possible smart technology applications to support mobile healthcare in the later stage of the pandemic. Section 4 summarizes this study and outlines some topics that may be investigated in the future.

2. Past Work

We reviewed the literature and reports on the applications of smart technologies to mobile healthcare. A summary is provided in Figure 1, showing the number of references related to specific smart technology applications to mobile healthcare since 2020. Some smart technologies, such as blockchain [37,38] and the Internet of things (IoT) [39,40], that are relatively hot in research but not yet popularized [41,42], were excluded from the scope of experimental comparison in this study.

2.1. Comparing Smart Technology Applications to Support Mobile Healthcare before and within the COVID-19 Pandemic

Smart technology applied during the COVID-19 pandemic had the following differences from those applied before the outbreak.
First, users’ motivations for applying smart technologies have changed. Before the outbreak of the COVID-19 pandemic, smart technology applications were called for a healthy life. In contrast, during the pandemic, applications are mainly to avoid infection (i.e., the prevention of diseases).
In addition, some innovative ways of applying smart technologies within the COVID-19 pandemic have emerged. Smart technologies are applied both before and within the COVID-19 pandemic. However, during the COVID-19 pandemic, many existing smart technologies have been innovatively applied: For example, apps were designed to help find where to buy facial masks, remind a user to wear a facial mask or detect whether a user is wearing a facial mask [44]. According to the statistics by Collado-Borrell et al. [45], most of the apps developed at this stage were used to provide information or news about COVID-19, record symptoms, and trace contacts. In addition, smart watches were also applied to track people’s health conditions (including heart rate and sleep duration) and physical activities (including gesture, motion, step count and movement). This kind of application was relatively rare for smart watches before the pandemic.
Further, users’ acceptance of smart technology applications has increased. During the epidemic, users’ acceptance of certain smart technology applications has increased significantly. For example, according to the survey by Kim et al. [19], hotel tourists were more satisfied with services (including greetings, delivery of goods, cleaning, etc.) provided by humans than by robots before the COVID-19 pandemic but felt more at ease if these services were provided by robots during the pandemic.
Furthermore, new smart technologies are still being proposed. Some new smart technologies have been developed and applied during the COVID-19 pandemic. For example, a novel smart bracelet, as an application of the Internet of things, was developed and applied during the COVID-19 pandemic to measure the body temperature and blood oxygen level of a patient [20]. In addition, the GPS tracker on the smart bracelet helps ensure the patient’s commitment to quarantine and social distancing. Sociometric badges [21] can also be applied to fulfill similar purposes. These smart technologies were previously used to promote interpersonal communication [22,23,24,25], but now they can be used to monitor and restrict interpersonal interaction. Smart devices like smart bracelets are undoubtedly an important part of a wireless medical sensor network [26]. During the COVID-19 pandemic, a wireless medical sensor network can not only monitor the health conditions of patients ubiquitously but also reduce the contact between doctors (and nurses) and patients.

2.2. Possible Developments in Smart Technology Applications to Support Mobile Healthcare after the COVID-19 Pandemic

Some possible developments in smart technology applications to support mobile healthcare in the later stages of (or after) the COVID-19 pandemic is estimated as follows.
First, the motivations for applying smart technologies change again. After the COVID-19 pandemic, an increasingly strong motivation for applying smart technologies is to restore the freedom of mobility. A vaccine passport is an obvious example [27]. Only travelers who have been vaccinated are allowed to enter some countries or regions [29,46]. In addition, to promote safe cross-border travel, websites or apps for booking rooms, seats, or restaurants across countries also consider the requirements for vaccination in tourist destinations.
Second, the demand for some smart technology applications may disappear. For example, after widespread vaccination, the need to avoid human contact with smart technologies, such as robots and drones is no longer strong. In addition, the costs and expenses of widespread deployment of robots are also unbearable. For these reasons, applications of robots and drones may fade out after the pandemic. In addition, in the survey of Sierra Marín et al. [47], some hospital staff were afraid of being replaced by robots.
In addition, the requirements for the effectiveness of a smart technology application will become higher. The performances of some existing smart technology applications are not sufficiently high. For example, according to the experiment of Suhartina and Abuzairi [48], the blood oxygen level detected by a smart bracelet is usually lower than the actual value. The deviation may exceed 5%. In addition, smart bracelets, smart watches, and smart body temperature monitors (i.e., infrared cameras/thermometers) are subject to the same limitation—that is, a patient is contagious two days before the onset of obvious symptoms [49], while pre-symptomatic or asymptomatic patients cause more than half of infections. During the COVID-19 pandemic, most users can tolerate this problem. However, after the pandemic is over, users will have higher requirements for the effectiveness of a smart technology application.
Further, smart technology applications must be enhanced by software developments. For example, to solve the problem that the detection accuracy of a smart bracelet is not high enough, researchers have suggested that a patient must continue to record any symptom accompanied with the detection data of the smart bracelet to conduct a comprehensive judgment using special algorithms [49]. Similarly, a number of studies [50,51,52] also recommended combining smartwatch detection results with self-reported symptoms to determine whether an individual has COVID-19 after symptoms appear.
Furthermore, the cost-effectiveness of a smart technology application will be more rigorously examined. For example, when the pandemic is severe, managing the massive amounts of heterogeneous data [53] transmitted through a wireless medical sensor network requires huge hardware investment [26], which limits its application to a small, experimental space. For this reason, after the COVID-19 pandemic, the reliance on wireless medical sensor networks will be greatly reduced. In addition, compared with smart bracelets, smart watches are equipped with more sensors, so they are more powerful in tracking people’s health conditions and physical activities. However, smart watches are usually more expensive than smart bracelets. Nevertheless, smart watches are more sophisticated than smart bracelets and are expected to be continuously used after the COVID-19 pandemic. Further, since high body temperature is one of the signs of COVID-19, remote temperature scanners have been widely applied to screen people who may be infectious [54]. Although the accuracy of this is not high [55], this technology is quick, simple, mature and non-invasive, and can prevent the spread of other diseases. Therefore, after the pandemic is over, it is expected to be continuously applied.
Table 1 summarizes the discussion result. It can be seen from this table that the motivations for applying smart technologies have changed from promoting a healthy life before the COVID-19 outbreak to avoiding infection during the pandemic. After the COVID-19 pandemic is over, the motivation is to promote healthy mobility.

3. Assessing Smart Technology Applications after the COVID-19 Pandemic

Based on the above discussion, the CFGM-FTOPSIS [30] is applied to assess a smart technology application to support mobile healthcare after the COVID-19 pandemic. A fuzzy approach is suitable for considering the many uncertainties that people face during the COVID-19 pandemic. Without loss of generality, all fuzzy parameters and variables in the proposed methodology are given in or approximated by triangular fuzzy numbers (TFNs). The procedure for the fuzzy MCDM approach is illustrated in Figure 2. The first step is to derive the fuzzy priorities of criteria for assessing a smart technology application.
In the CFGM-FTOPSIS approach, first, the decision-maker expresses his/her opinion on the relative priority of a criterion over another in linguistic (or semantic) terms. These linguistic terms are usually mapped to TFNs within [1,9,56] (see Table 2). The results are summarized with a fuzzy judgment matrix A ˜ = [ a ˜ i j ] ; i, j = 1 ~ n. a ˜ i j is the relative priority of criterion i over criterion j. The TFNs for these linguistic terms overlap to embody the uncertainty in choosing between them.

3.1. Deriving the Fuzzy Priorities of Criteria Using CFGM

The fuzzy judgment matrix meets the following conditions:
d e t ( A ˜ ( ) λ ˜ I ) = 0
( A ˜ ( ) λ ˜ I ) ( × ) x ˜ = 0
λ ˜ is the fuzzy maximal eigenvalue; x ˜ is the fuzzy eigenvector. (−) and (×) denote fuzzy subtraction and multiplication [58], respectively. The fuzzy priorities of criteria, indicated with { w ˜ i | i = 1 ~ n } , can be approximated using fuzzy geometric mean (FGM) [56] as:
w i 1 1 1 + m i j = 1 n a m j 3 n j = 1 n a i j 1 n
w i 2 1 1 + m i j = 1 n a m j 2 n j = 1 n a i j 2 n
w i 3 1 1 + m i j = 1 n a m j 1 n j = 1 n a i j 3 n
To improve the approximation precision, Chen and Wang [30] proposed the CFGM approach to tune the values of fuzzy priorities:
w i 1 1 1 + m i j = 1 n a m j 3 n j = 1 n a i j 1 n + w i ( c ) 1 1 + m i j = 1 n a m j 2 n j = 1 n a i j 2 n
w i 2 w i ( c )
w i 3 1 1 + m i j = 1 n a m j 1 n j = 1 n a i j 3 n + w i ( c ) 1 1 + m i j = 1 n a m j 2 n j = 1 n a i j 2 n
where w i ( c ) is the (crisp) priority of criterion i derived from the defuzzified judgment matrix using an eigen analysis:
d e t ( A 2 λ 2 I ) = 0
( A 2 λ 2 I ) x 2 = 0
Subsequently, λ ˜ max can be estimated as:
λ max , 1 1 + 1 n i = 1 n j i a i j 1 w j 1 w i 3
λ max , 2 1 + 1 n i = 1 n j i a i j 2 w j 2 w i 2
λ max , 3 1 + 1 n i = 1 n j i a i j 3 w j 3 w i 1
A ˜ is consistent if:
C R ˜ ( A ˜ ) 0.1
where:
C R 1 ( A ˜ ) = max ( 0 , λ max , 1 n ( n 1 ) R I )
C R 2 ( A ˜ ) = λ max , 2 n ( n 1 ) R I
C R 3 ( A ˜ ) = λ max , 3 n ( n 1 ) R I
RI denotes random consistency index [59]. It is noteworthy that C R 1 ( A ˜ ) is not necessarily associated with λ max , 1 , while C R 3 ( A ˜ ) is usually determined by λ max , 3 . However, C R 3 ( A ˜ ) considers the most inconsistent case that rarely happens. Therefore, in practice, it is better that C R 2 ( A ˜ ) 0.1 ~ 0.3 and C R 1 ( A ˜ ) = 0 . Otherwise, the decision maker needs to modify his/her pairwise comparison results.

3.2. Assessing a Smart Technology Application Using FTOPSIS

Letting the performance of smart technology application q in optimize criterion i be indicated with p ˜ q i . To facilitate the aggregation, p ˜ q i is normalized as [60,61]:
ρ ˜ q i = p ˜ q i ϕ = 1 Q p ˜ ϕ i 2 = 1 1 + ϕ q ( p ˜ ϕ i p ˜ q i ) 2
After expansion,
ρ q i 1 = 1 1 + ϕ q ( p ϕ i 3 p q i 1 ) 2
ρ q i 2 = 1 1 + ϕ q ( p ϕ i 2 p q i 2 ) 2
ρ q i 3 = 1 1 + ϕ q ( p ϕ i 1 p q i 3 ) 2
The fuzzy priority of the criterion is multiplied by the normalized performance to derive the fuzzy prioritized score as:
s ˜ q i = w ˜ i ( × ) ρ ˜ q i
Equivalently,
s q i 1 = w i 1 ρ q i 1
s q i 2 = w i 2 ρ q i 2
s q i 3 = w i 3 ρ q i 3
Then, two reference points representing the theoretically best and worst alternatives are defined as Λ ˜ i + and Λ ˜ i , respectively:
Λ ˜ i + = max q s ˜ q i ( max q s q i 1 , max q s q i 2 , max q s q i 3 )
Λ ˜ i = min q s ˜ q i ( min q s q i 1 , min q s q i 2 , min q s q i 3 )
The overall performance of a smart technology application is evaluated by comparing its (Euclidean) distances to the two reference points:
U ˜ q = d ˜ q d ˜ q + ( + ) d ˜ q = ( 1 d q 3 + d q 1 + 1 , 1 d q 2 + d q 2 + 1 , 1 d q 1 + d q 3 + 1 )
where:
d ˜ q + = i = 1 n ( Λ ˜ i + ( ) s ˜ q i ) 2 = ( i = 1 n max ( Λ i 1 + s q i 3 , 0 ) 2 , i = 1 n ( Λ i 2 + s q i 2 ) 2 , i = 1 n ( Λ i 3 + s q i 1 ) 2 )
d ˜ q = i = 1 n ( s ˜ q i ( ) Λ ˜ i ) 2 = ( i = 1 n max ( s q i 1 Λ i 3 , 0 ) 2 , i = 1 n ( s q i 2 Λ i 2 ) 2 , i = 1 n ( s q i 3 Λ i 1 ) 2 )

4. Case Study

Background

The proposed methodology has been applied to assess and compare several potential smart technology applications for supporting mobile healthcare after the COVID-19 pandemic from the literature and reports.
The decision-makers were the members of a one-year project entitled “Smart Technology Applications for Supporting Medical and Health Care after the COVID-19 Pandemic”, including an industrial engineering professor, an information technology engineer, and a healthcare technology researcher.
From the discussion in Section 3, they listed all possible factors that should be considered. Then, through brainstorming, the less influential factors were deleted one by one. Finally, the following factors were considered critical when assessing a smart technology application for supporting mobile healthcare after the COVID-19 pandemic:
  • Can it provide value-added services based on vaccination information [27,28,29]?
  • Is it cost effective [20,26,43,44]?
  • Can it enhance people’s mobility healthily [18,29]?
  • Is it necessary or irreplaceable [18,41,42]?
  • Can it be combined with other smart technology applications to achieve synergy [20,26]?
  • Is it easy to implement and maintain [41,42,54]?
The relative priorities of these critical factors were compared in pairs. After discussion, the three decision-makers jointly selected a linguistic variable representing the relative priority. The results are summarized in Table 3.
Based on Table 3, the following fuzzy judgment matrix was constructed:
A ˜ = [ 1 ( 1 , 2 , 4 ) ( 1 , 3 , 5 ) ( 1 , 3 , 5 ) ( 3 , 5 , 7 ) 1 ( 2 , 4 , 6 ) ( 3 , 5 , 7 ) ( 2 , 4 , 6 ) ( 2 , 4 , 6 ) ( 3 , 5 , 7 ) 1 ( 3 , 5 , 7 ) ( 3 , 5 , 7 ) ( 3 , 5 , 7 ) 1 ( 3 , 5 , 7 ) ( 3 , 5 , 7 ) 1 ( 1 , 2 , 4 ) 1 ]
C R ˜ ( A ˜ ) = ( 0.00 , 0.13 , 6.16 ) , which was considered sufficiently consistent considering the uncertainty of the problem under investigation.
To derive the fuzzy priorities of criteria from the fuzzy judgment matrix, the CFGM approach was applied. The CFGM approach was implemented using Excel on a PC with an i7-7700 CPU of 3.6 GHz and 8 GB of RAM (ASUS, Hsinchu City, Taiwan). The results are shown in Figure 3. Obviously, “healthy mobility” was more important than the others, followed by “value-added services”
Based on the derived fuzzy priorities of criteria, nine potential smart technology applications (see Table 4) were assessed and compared using FTOPSIS [20,54,55]. References that support these smart technology applications are also provided. These smart technology applications were enumerated and selected by project members after brainstorming. Therefore, this list did not cover all possible smart technology applications to mobile healthcare. In other studies, the smart technology applications chosen by different decision-makers will be different.
The criteria for evaluating the performances of these smart technology applications have been established, as summarized in Table 5. All performances are normalized into [1,5] to facilitate the subsequent aggregation. The evaluation results are summarized in Table 6.
First, the performance of a smart technology application in optimizing each criterion was normalized using fuzzy distributive normalization. The results are summarized in Table A1 of Appendix A.
After multiplying the derived fuzzy priorities to the normalized performances, the fuzzy prioritized scores of smart technology applications were obtained. The results are summarized in Table A2 of Appendix A.
Based on the fuzzy prioritized scores of all smart technology applications, the fuzzy ideal point and the fuzzy anti-ideal point were respectively defined in Table A3 of Appendix A. Subsequently, the distances from each smart technology application, to the two reference points were measured respectively. The results are summarized in Table A4 of Appendix A. A smart technology application was better if it was closer to the ideal solution but farther from the anti-ideal solution.
Finally, the overall performance of each smart technology application, in terms of its fuzzy closeness, was evaluated. The results are shown in Table 7. The overall performance was also defuzzified using the center-of-gravity (COG) method [64]. Based on the defuzzification results, the smart technology applications were ranked.
According to the experimental results, the following discussion was made:
(1)
“Vaccine passport and related applications” was the best smart technology application to support mobile healthcare after the COVID-19 pandemic, followed by “smart watches” and “contact tracing apps”.
(2)
For comparison, the prevalent FGM method [55] was applied to this case. The fuzzy priorities of criteria were derived as:
w ˜ 1 = ( 0.084 , 0.201 , 0.381 )
w ˜ 2 = ( 0.078 , 0.169 , 0.326 )
w ˜ 3 = ( 0.240 , 0.440 , 0.633 )
w ˜ 4 = ( 0.051 , 0.103 , 0.236 )
w ˜ 5 = ( 0.019 , 0.040 , 0.104 )
w ˜ 6 = ( 0.023 , 0.048 , 0.116 )
Subsequently, fuzzy weighted average (FWA) was applied to evaluate the overall performance of a smart technology application to support mobile healthcare after the COVID-19 pandemic. The evaluation results are summarized in Table 8. The top two smart technology applications were also “vaccine passport and related applications” and “smart watches”. However, the ranking results of other smart technology applications were slightly different from those obtained using the proposed methodology.
(3)
In addition, the fuzzy extent analysis (FEA) method proposed by Chang [65] was also applied to this case. The priorities of criteria derived using FEA were crisp values. Based on the derived priorities, the overall performance of a smart technology application was evaluated using FWA. The evaluation results are presented in Table 9. “Vaccine passport and related applications” and “smart watches” outperformed the other smart technology applications. In addition, the ranking results of smart technology applications were somewhat different from those obtained using the previous two methods.
(4)
If five smart technology applications were to be selected, the results using various methods are compared in Table 10. The same smart technology applications were recommended, showing the robustness of the evaluation results.

5. Discussion and Conclusions

Applications of smart technologies have widely improved mobile healthcare before the COVID-19 pandemic, and it will be the same after the pandemic. However, smart technology applications for supporting mobile healthcare after the COVID-19 pandemic may not be the same as those before the pandemic. To address this issue, this study compares smart technology applications to support mobile healthcare within the COVID-19 pandemic with those before the pandemic, so as to estimate possible developments in smart technology applications after the COVID-19 pandemic. In addition, to quantitatively assess and compare possible smart technology applications to support mobile healthcare after the COVID-19 pandemic, the CFGM-FTOPSIS approach is applied.
The effectiveness of the proposed methodology was validated by applying it to nine possible smart technology applications to support mobile healthcare after the COVID-19 pandemic. Two existing fuzzy MCDM methods were also applied to these smart technology applications for comparison. According to the experimental results, the following conclusions were made:
“Vaccine passport and related applications” and “smart watches” were the best smart technology applications to support mobile healthcare after the COVID-19 pandemic. These two smart technology applications are already mature, which may be the main reason for their preference. The top five smart technology applications included “contact tracing apps”, “smart bracelets”, and “wireless medical sensor networks”. These smart technology applications have a common feature, that is, they can (or have the potential) to support a large number of users.
(1)
In contrast, although remote body temperature monitoring was a very prevalent smart technology application, it was not recommended. The reason should be limited functions and insufficient effectiveness. At the peak of the COVID-19 pandemic, people were more tolerant of these shortcomings.
(2)
Except for the two top performers, the rankings of other smart technologies were different from those calculated using existing methods. Such differences resulted from errors in estimating the priorities of critical factors. Taking FEA as an example; it overestimated the priorities of “cost effectiveness” and “necessity or irreplaceability” but underestimated the priority of “healthy mobility”. As a result, the ranking of “contact tracing app” fell to the fourth. The CFGM method applied in this study solved this problem in an efficient and effective way.
(3)
Nevertheless, if five smart technology applications were to be recommended, the results using various methods were the same, supporting the robustness of the recommendation results.
This study has the following limitations:
(1)
Although the critical factors considered in this study referred to related literature or reports, these critical factors were subjectively selected by the researchers. Critical factors considered by other researchers will not be the same.
(2)
In addition, the relative priorities of critical factors were subjectively determined by the decision makers and are susceptible to personal bias. If more decision makers can be involved to make a joint decision, subjective bias can be avoided.
Hopefully, the conclusions drawn in this study will be examined in the near future. In addition, there is still considerable room for the development and application of smart technologies in this field.

Author Contributions

All authors contributed equally to the writing of this paper. Data curation, methodology and writing original draft: T.C. and Y.-C.W.; writing—review and editing: T.C. and Y.-C.W. All authors have read and agreed to the published version of the manuscript.

Funding

This research received no external funding.

Institutional Review Board Statement

Not applicable.

Informed Consent Statement

Not applicable.

Data Availability Statement

Data is contained within the article or Appendix A.

Conflicts of Interest

The authors declare that there is no conflict of interest regarding the publication of this article.

Appendix A

Table A1. Normalized performances of smart technology applications.
Table A1. Normalized performances of smart technology applications.
q ρ ˜ q 1 ρ ˜ q 2 ρ ˜ q 3 ρ ˜ q 4 ρ ˜ q 5 ρ ˜ q 6
1(0.26, 0.41, 0.62)(0.17, 0.36, 0.64)(0.3, 0.45, 0.57)(0.33, 0.56, 0.83)(0.13, 0.28, 0.5)(0.13, 0.25, 0.44)
2(0.13, 0.26, 0.45)(0, 0, 0.22)(0.11, 0.22, 0.4)(0.16, 0.35, 0.64)(0.27, 0.45, 0.68)(0.13, 0.25, 0.44)
3(0.13, 0.26, 0.45)(0.17, 0.36, 0.64)(0.23, 0.36, 0.55)(0.16, 0.35, 0.64)(0.13, 0.28, 0.5)(0.26, 0.4, 0.61)
4(0.26, 0.41, 0.62)(0.17, 0.36, 0.64)(0.23, 0.36, 0.55)(0.16, 0.35, 0.64)(0.27, 0.45, 0.68)(0.13, 0.25, 0.44)
5(0, 0.1, 0.27)(0.34, 0.58, 0.83)(0.11, 0.22, 0.4)(0.16, 0.35, 0.64)(0.27, 0.45, 0.68)(0.26, 0.4, 0.61)
6(0, 0.1, 0.27)(0.17, 0.36, 0.64)(0.11, 0.22, 0.4)(0, 0.14, 0.41)(0, 0.11, 0.31)(0.33, 0.5, 0.64)
7(0.34, 0.52, 0.65)(0, 0.14, 0.41)(0.23, 0.36, 0.55)(0.16, 0.35, 0.64)(0.13, 0.28, 0.5)(0, 0.1, 0.27)
8(0.13, 0.26, 0.45)(0, 0, 0.22)(0.23, 0.36, 0.55)(0, 0.14, 0.41)(0.13, 0.28, 0.5)(0.13, 0.25, 0.44)
9(0.26, 0.41, 0.62)(0.17, 0.36, 0.64)(0.23, 0.36, 0.55)(0, 0.14, 0.41)(0.13, 0.28, 0.5)(0.26, 0.4, 0.61)
Table A2. Fuzzy prioritized scores of smart technology applications.
Table A2. Fuzzy prioritized scores of smart technology applications.
q s ˜ q 1 s ˜ q 2 s ˜ q 3 s ˜ q 4 s ˜ q 5 s ˜ q 6
1(0.02, 0.08, 0.23)(0.01, 0.06, 0.21)(0.07, 0.2, 0.36)(0.02, 0.06, 0.2)(0, 0.01, 0.05)(0, 0.01, 0.05)
2(0.01, 0.05, 0.17)(0, 0, 0.07)(0.03, 0.1, 0.25)(0.01, 0.04, 0.15)(0.01, 0.02, 0.07)(0, 0.01, 0.05)
3(0.01, 0.05, 0.17)(0.01, 0.06, 0.21)(0.06, 0.16, 0.35)(0.01, 0.04, 0.15)(0, 0.01, 0.05)(0.01, 0.02, 0.07)
4(0.02, 0.08, 0.23)(0.01, 0.06, 0.21)(0.06, 0.16, 0.35)(0.01, 0.04, 0.15)(0.01, 0.02, 0.07)(0, 0.01, 0.05)
5(0, 0.02, 0.1)(0.03, 0.1, 0.27)(0.03, 0.1, 0.25)(0.01, 0.04, 0.15)(0.01, 0.02, 0.07)(0.01, 0.02, 0.07)
6(0, 0.02, 0.1)(0.01, 0.06, 0.21)(0.03, 0.1, 0.25)(0, 0.02, 0.1)(0, 0, 0.03)(0.01, 0.02, 0.07)
7(0.03, 0.1, 0.24)(0, 0.02, 0.13)(0.06, 0.16, 0.35)(0.01, 0.04, 0.15)(0, 0.01, 0.05)(0, 0, 0.03)
8(0.01, 0.05, 0.17)(0, 0, 0.07)(0.06, 0.16, 0.35)(0, 0.02, 0.1)(0, 0.01, 0.05)(0, 0.01, 0.05)
9(0.02, 0.08, 0.23)(0.01, 0.06, 0.21)(0.06, 0.16, 0.35)(0, 0.02, 0.1)(0, 0.01, 0.05)(0.01, 0.02, 0.07)
Table A3. Fuzzy ideal point and fuzzy anti-ideal point.
Table A3. Fuzzy ideal point and fuzzy anti-ideal point.
Reference Point Λ ˜ 1 + / Λ ˜ 2 + / Λ ˜ 3 + / Λ ˜ 4 + / Λ ˜ 5 + / Λ ˜ 6 + /
Fuzzy ideal point(0.03, 0.1, 0.24)(0.03, 0.1, 0.27)(0.07, 0.2, 0.36)(0.02, 0.06, 0.2)(0.01, 0.02, 0.07)(0.01, 0.02, 0.07)
Fuzzy anti-ideal point(0, 0.02, 0.1)(0, 0, 0.07)(0.03, 0.1, 0.25)(0, 0.02, 0.1)(0, 0, 0.03)(0, 0, 0.03)
Table A4. Distances between each smart technology application and the two reference points.
Table A4. Distances between each smart technology application and the two reference points.
q d ˜ q + d ˜ q
1(0, 0.04, 0.49)(0, 0.14, 0.5)
2(0, 0.15, 0.54)(0, 0.04, 0.34)
3(0, 0.08, 0.51)(0, 0.09, 0.45)
4(0, 0.06, 0.51)(0, 0.11, 0.48)
5(0, 0.13, 0.53)(0, 0.1, 0.41)
6(0, 0.14, 0.54)(0, 0.06, 0.35)
7(0, 0.09, 0.51)(0, 0.11, 0.45)
8(0, 0.13, 0.52)(0, 0.07, 0.39)
9(0, 0.07, 0.51)(0, 0.11, 0.46)

References

  1. Chen, T.; Chiu, M.C. Smart technologies for assisting the life quality of persons in a mobile environment: A review. J. Ambient Intell. Humaniz. Comput. 2018, 9, 319–327. [Google Scholar] [CrossRef]
  2. van Doorn, M. What Does SMART Technology Actually Mean? Available online: http://labs.sogeti.com/wat-smart-technology-actually-mean/ (accessed on 14 September 2021).
  3. Bayahya, A.Y.; Alhalabi, W.; AlAmri, S.H. Smart health system to detect dementia disorders using virtual reality. Healthcare 2021, 9, 810. [Google Scholar] [CrossRef]
  4. Park, S.H.; Won, S.H.; Lee, J.B.; Kim, S.W. Smart home–digitally engineered domestic life. Pers. Ubiquitous Comput. 2003, 7, 189–196. [Google Scholar] [CrossRef]
  5. Pandian, P.S.; Mohanavelu, K.; Safeer, K.P.; Kotresh, T.M.; Shakunthala, D.T.; Gopal, P.; Padaki, V.C. Smart Vest: Wearable multi-parameter remote physiological monitoring system. Med. Eng. Phys. 2008, 30, 466–477. [Google Scholar] [CrossRef]
  6. Phan, D.; Siong, L.Y.; Pathirana, P.N.; Seneviratne, A. Smartwatch: Performance evaluation for long-term heart rate monitoring. In Proceedings of the International Symposium on Bioelectronics and Bioinformatics, Beijing, China, 14–17 October 2015; pp. 144–147. [Google Scholar]
  7. Reeder, B.; David, A. Health at hand: A systematic review of smart watch uses for health and wellness. J. Biomed. Inform. 2016, 63, 269–276. [Google Scholar] [CrossRef]
  8. Burlea-Schiopoiu, A.; Ferhati, K. The managerial implications of the key performance indicators in healthcare sector: A cluster analysis. Healthcare 2020, 9, 19. [Google Scholar] [CrossRef]
  9. Shah, I. Fighting COVID-19 with Police Patrol Robots and Drones. Available online: https://www.police.gov.sg/media-room/features/fighting-covid-19-with-police-patrol-robots-and-drones (accessed on 14 September 2021).
  10. Huang, Z.; Huang, X. A study on the application of voice interaction in automotive human machine interface experience design. AIP Conf. Proc. 2018, 1955, 040074. [Google Scholar]
  11. Longo, F.; Padovano, A.; Umbrello, S. Value-oriented and ethical technology engineering in industry 5.0: A human-centric perspective for the design of the factory of the future. Appl. Sci. 2020, 10, 4182. [Google Scholar] [CrossRef]
  12. Guo, H.; Meng, Y.; Chi, S.; Ding, P. Design of human-machine interaction system based on Android mobile phone gesture and voice control. Nanjing Xinxi Gongcheng Daxue Xuebao 2019, 11, 216–220. [Google Scholar]
  13. Periša, M.; Kuljanić, T.M.; Cvitić, I.; Kolarovszki, P. Conceptual model for informing user with innovative smart wearable device in industry 4.0. Wirel. Netw. 2021, 27, 1615–1626. [Google Scholar] [CrossRef]
  14. Nichols, G. Disinfecting Robots to Fight Coronavirus Run into Travel Bans. Available online: https://www.zdnet.com/article/disinfecting-robots-to-fight-coronavirus-run-into-travel-bans/ (accessed on 12 September 2021).
  15. Bian, S.; Zhou, B.; Lukowicz, P. Social distance monitor with a wearable magnetic field proximity sensor. Sensors 2020, 20, 5101. [Google Scholar] [CrossRef]
  16. Wray, S. UK Council’s Beach Crowd Management App to Be Scaled Nationally. Available online: https://cities-today.com/uk-councils-beach-crowd-management-app-to-be-scaled-nationally/ (accessed on 12 September 2021).
  17. Bashir, M.F.; Benjiang, M.A.; Shahzad, L. A brief review of socio-economic and environmental impact of COVID-19. Air Qual. Atmos. Health 2020, 13, 1403–1409. [Google Scholar] [CrossRef]
  18. Ting, D.S.W.; Carin, L.; Dzau, V.; Wong, T.Y. Digital technology and COVID-19. Nat. Med. 2020, 26, 459–461. [Google Scholar] [CrossRef] [Green Version]
  19. Kim, S.S.; Kim, J.; Badu-Baiden, F.; Giroux, M.; Choi, Y. Preference for robot service or human service in hotels? Impacts of the COVID-19 pandemic. Int. J. Hosp. Manag. 2021, 93, 102795. [Google Scholar] [CrossRef]
  20. Ennafiri, M.; Mazri, T. Internet of things for smart healthcare: A review on a potential IOT based system and technologies to control COVID-19 pandemic. Innov. Smart Cities Appl. 2021, 4, 1256–1269. [Google Scholar]
  21. MIT Media Laboratory. Sociometric Badges. Available online: https://hd.media.mit.edu/badges/ (accessed on 12 October 2021).
  22. Stefanini, A.; Aloini, D.; Gloor, P. Silence is golden: The role of team coordination in health operations. Int. J. Oper. Prod. Manag. 2020, 40, 1421–1447. [Google Scholar] [CrossRef]
  23. Ito-Masui, A.; Kawamoto, E.; Esumi, R.; Imai, H.; Shimaoka, M. Sociometric wearable devices for studying human behavior in corporate and healthcare workplaces. BioTechniques 2021, 71, 392–399. [Google Scholar] [CrossRef]
  24. Stefanini, A.; Aloini, D.; Gloor, P.; Pochiero, F. Patient satisfaction in emergency department: Unveiling complex interactions by wearable sensors. J. Bus. Res. 2021, 129, 600–611. [Google Scholar] [CrossRef]
  25. Kawamoto, E.; Ito-Masui, A.; Esumi, R.; Imai, H.; Shimaoka, M. How ICU patient severity affects communicative interactions between healthcare professionals: A study utilizing wearable sociometric badges. Front. Med. 2020, 7, 606987. [Google Scholar] [CrossRef]
  26. Ali, S.; Singh, R.P.; Javaid, M.; Haleem, A.; Pasricha, H.; Suman, R.; Karloopia, J. A review of the role of smart wireless medical sensor network in COVID-19. J. Ind. Integr. Manag. 2020, 5, 413–425. [Google Scholar] [CrossRef]
  27. Hall, M.A.; Studdert, D.M. Vaccine passport” certification—policy and ethical considerations. N. Engl. J. Med. 2021, 385, e32. [Google Scholar] [CrossRef] [PubMed]
  28. Research and Markets. Mobile Health (mHealth) Market—Growth, Trends, COVID-19 Impact, and Forecasts (2021–2026). Available online: https://www.researchandmarkets.com/reports/4520220/mobile-health-mhealth-market-growth-trends (accessed on 21 October 2021).
  29. Heijmans, P. Singapore PM Pushes for Living with COVID, without the Fear. Available online: https://www.bloomberg.com/news/articles/2021-10-09/singapore-premier-pushes-for-living-with-covid-without-the-fear (accessed on 12 October 2021).
  30. Chen, T.; Wang, Y.C. A calibrated piecewise-linear FGM approach for travel destination recommendation during the COVID-19 pandemic. Appl. Soft Comput. 2021, 109, 107535. [Google Scholar] [CrossRef]
  31. Hosseini, S.M.; Paydar, M.M.; Hajiaghaei-Keshteli, M. Recovery solutions for ecotourism centers during the COVID-19 pandemic: Utilizing Fuzzy DEMATEL and Fuzzy VIKOR methods. Expert Syst. Appl. 2021, 185, 115594. [Google Scholar] [CrossRef] [PubMed]
  32. Ocampo, L.; Yamagishi, K. Modeling the lockdown relaxation protocols of the Philippine government in response to the COVID-19 pandemic: An intuitionistic fuzzy DEMATEL analysis. Socio-Econ. Plan. Sci. 2020, 72, 100911. [Google Scholar] [CrossRef]
  33. Ghorui, N.; Ghosh, A.; Mondal, S.P.; Bajuri, M.Y.; Ahmadian, A.; Salahshour, S.; Ferrara, M. Identification of dominant risk factor involved in spread of COVID-19 using hesitant fuzzy MCDM methodology. Results Phys. 2021, 21, 103811. [Google Scholar] [CrossRef] [PubMed]
  34. Castillo, O.; Melin, P. A novel method for a COVID-19 classification of countries based on an intelligent fuzzy fractal approach. Healthcare 2021, 9, 196. [Google Scholar] [CrossRef] [PubMed]
  35. Mahmoudi, M.R.; Baleanu, D.; Mansor, Z.; Tuan, B.A.; Pho, K.H. Fuzzy clustering method to compare the spread rate of COVID-19 in the high risks countries. Chaos Solitons Fractals 2020, 140, 110230. [Google Scholar] [CrossRef]
  36. Baker, S.B.; Xiang, W.; Atkinson, I. Internet of things for smart healthcare: Technologies, challenges, and opportunities. IEEE Access 2017, 5, 26521–26544. [Google Scholar] [CrossRef]
  37. Khan, F.A.; Asif, M.; Ahmad, A.; Alharbi, M.; Aljuaid, H. Blockchain technology, improvement suggestions, security challenges on smart grid and its application in healthcare for sustainable development. Sustain. Cities Soc. 2020, 55, 102018. [Google Scholar] [CrossRef]
  38. Khatoon, A. A blockchain-based smart contract system for healthcare management. Electronics 2020, 9, 94. [Google Scholar] [CrossRef] [Green Version]
  39. Raj, J.S. A novel information processing in IoT based real time health care monitoring system. J. Electron. 2020, 2, 188–196. [Google Scholar]
  40. Patan, R.; Ghantasala, G.P.; Sekaran, R.; Gupta, D.; Ramachandran, M. Smart healthcare and quality of service in IoT using grey filter convolutional based cyber physical system. Sustain. Cities Soc. 2020, 59, 102141. [Google Scholar] [CrossRef]
  41. Jaiswal, R.; Agarwal, A.; Negi, R. Smart solution for reducing the COVID-19 risk using smart city technology. IET Smart Cities 2020, 2, 82–88. [Google Scholar] [CrossRef]
  42. Davis, R. Integrating digital technologies and data driven telemedicine into smart healthcare during the COVID-19 pandemic. Am. J. Med Res. 2020, 7, 22–28. [Google Scholar]
  43. Google Scholar. Smart Technology Mobile Health. Available online: https://scholar.google.com (accessed on 21 October 2021).
  44. Kulkarni, A.; Vishwanath, A.; Shah, C. Implementing a Real-Time, AI-Based, Face Mask Detector Application for COVID-19. Available online: https://developer.nvidia.com/blog/implementing-a-real-time-ai-based-face-mask-detector-application-for-covid-19/ (accessed on 12 September 2021).
  45. Collado-Borrell, R.; Escudero-Vilaplana, V.; Villanueva-Bueno, C.; Herranz-Alonso, A.; Sanjurjo-Saez, M. Features and functionalities of smartphone apps related to COVID-19: Systematic search in app stores and content analysis. J. Med Internet Res. 2020, 22, e20334. [Google Scholar] [CrossRef]
  46. Wu, H.C.; Wang, Y.C.; Chen, T.C.T. Assessing and comparing COVID-19 intervention strategies using a varying partial consensus fuzzy collaborative intelligence approach. Mathematics 2020, 8, 1725. [Google Scholar] [CrossRef]
  47. Sierra Marín, S.D.; Gomez-Vargas, D.; Céspedes, N.; Múnera, M.; Roberti, F.; Barria, P.; Ramamoorthy, S.; Becker, M.; Carelli, R.; Cifuentes, C.A. Expectations and perceptions of healthcare professionals for robot deployment in hospital environments during the COVID-19 pandemic. Front. Robot. AI 2021, 8, 102. [Google Scholar] [CrossRef]
  48. Suhartina, R.; Abuzairi, T. Pulse oximeter monitoring bracelet for COVID-19 patient using seeeduino. J. Ilm. Tek. Elektro Komput. Dan Inform. 2021, 7, 81–87. [Google Scholar]
  49. Brakenhoff, T.B.; Franks, B.; Goodale, B.M.; van de Wijgert, J.; Montes, S.; Veen, D.; Fredslund, E.K.; Rispens, T.; Risch, L.; Dowling, A.V.; et al. A prospective, randomized, single-blinded, crossover trial to investigate the effect of a wearable device in addition to a daily symptom diary for the remote early detection of SARS-CoV-2 infections (COVID-RED): A structured summary of a study protocol for a randomized controlled trial. Trials 2021, 22, 1–5. [Google Scholar]
  50. Mishra, T.; Wang, M.; Metwally, A.A.; Bogu, G.K.; Brooks, A.W.; Bahmani, A.; Alavi, A.; Celli, A.; Higgs, E.; Dagan-Rosenfeld, O.; et al. Pre-symptomatic detection of COVID-19 from smartwatch data. Nat. Biomed. Eng. 2020, 4, 1208–1220. [Google Scholar] [CrossRef]
  51. Zhu, T.; Watkinson, P.; Clifton, D.A. Smartwatch data help detect COVID-19. Nat. Biomed. Eng. 2020, 4, 1125–1127. [Google Scholar] [CrossRef]
  52. Niela-Vilén, H.; Auxier, J.; Ekholm, E.; Sarhaddi, F.; Asgari Mehrabadi, M.; Mahmoudzadeh, A.; Azimi, I.; Liljeberg, P.; Rahmani, A.M.; Axelin, A. Pregnant women’s daily patterns of well-being before and during the COVID-19 pandemic in Finland: Longitudinal monitoring through smartwatch technology. PLoS ONE 2021, 16, e0246494. [Google Scholar] [CrossRef] [PubMed]
  53. Mavrogiorgou, A.; Kiourtis, A.; Perakis, K.; Miltiadou, D.; Pitsios, S.; Kyriazis, D. Analyzing data and data sources towards a unified approach for ensuring end-to-end data and data sources quality in healthcare 4.0. Comput. Methods Programs Biomed. 2019, 181, 104967. [Google Scholar] [CrossRef] [PubMed]
  54. Inn, T.L. Smart city technologies take on COVID-19. Penang Inst. Issues 2020, 1–10. [Google Scholar]
  55. Tipton, M.; Mekjavic, I. Temperature Scanners Aren’t Good at Telling Who Has COVID-19–Here’s How to Fix That. Available online: https://theconversation.com/temperature-scanners-arent-good-at-telling-who-has-covid-19-heres-how-to-fix-that-153436 (accessed on 13 September 2021).
  56. Zheng, G.; Zhu, N.; Tian, Z.; Chen, Y.; Sun, B. Application of a trapezoidal fuzzy AHP method for work safety evaluation and early warning rating of hot and humid environments. Saf. Sci. 2012, 50, 228–239. [Google Scholar] [CrossRef]
  57. Chen, T.-C.T. Advances in Fuzzy Group Decision Making; Springer: Cham, Switzerland, 2021. [Google Scholar]
  58. Hanss, M. Applied Fuzzy Arithmetic; Springer: Berlin/Heidelberg, Germany, 2005. [Google Scholar]
  59. Saaty, T.L. Axiomatic foundation of the analytic hierarchy process. Manag. Sci. 1986, 32, 841–855. [Google Scholar] [CrossRef]
  60. Kutlu, A.C.; Ekmekçioğlu, M. Fuzzy failure modes and effects analysis by using fuzzy TOPSIS-based fuzzy AHP. Expert Syst. Appl. 2012, 39, 61–67. [Google Scholar] [CrossRef]
  61. Lima Junior, F.R.; Osiro, L.; Carpinetti, L.C.R. A comparison between Fuzzy AHP and Fuzzy TOPSIS methods to supplier selection. Appl. Soft Comput. 2014, 21, 194–209. [Google Scholar] [CrossRef]
  62. Kaiser, M.S.; Al Mamun, S.; Mahmud, M.; Tania, M.H. Healthcare robots to combat COVID-19. In COVID-19: Prediction, Decision-Making, and Its Impacts; Springer: Singapore, 2021; pp. 83–97. [Google Scholar]
  63. Abbas, R.; Michael, K. COVID-19 contact trace app deployments: Learnings from Australia and Singapore. IEEE Consum. Electron. Mag. 2020, 9, 65–70. [Google Scholar] [CrossRef]
  64. van Broekhoven, E.; De Baets, B. Fast and accurate center of gravity defuzzification of fuzzy system outputs defined on trapezoidal fuzzy partitions. Fuzzy Sets Syst. 2006, 157, 904–918. [Google Scholar] [CrossRef]
  65. Chang, D.Y. Applications of the extent analysis method on fuzzy AHP. Eur. J. Oper. Res. 1996, 95, 649–655. [Google Scholar] [CrossRef]
Figure 1. Number of references related to a specific smart technology application to mobile healthcare since 2020 [43].
Figure 1. Number of references related to a specific smart technology application to mobile healthcare since 2020 [43].
Healthcare 09 01461 g001
Figure 2. Procedure for the CFGM-FTOPSIS approach.
Figure 2. Procedure for the CFGM-FTOPSIS approach.
Healthcare 09 01461 g002
Figure 3. Procedure for the CFGM-FTOPSIS approach.
Figure 3. Procedure for the CFGM-FTOPSIS approach.
Healthcare 09 01461 g003
Table 1. Summary of the discussion result.
Table 1. Summary of the discussion result.
CharacteristicsBefore COVID-19Within COVID-19After COVID-19
MotivationsHealthy lifeAvoidance of infectionRestoring mobility
Users’ AcceptanceLow~ModerateVery highHigh
Increasingly Applied Smart Technologies
  • Smart watches
  • Restaurant recommendation apps (for healthy diets)
  • (Smart phones) Apps for outdoor exercise or fitness
  • Robots (or drones)
  • Smart body temperature monitors
  • Smart bracelets
  • Smart watches
  • Smart body temperature monitors
  • Smart watches
  • (Smart phones) vaccine passports
Decreasingly Applied Smart Technologies
  • Robots (or drones)
  • Smart body temperature monitors
  • Smart bracelets
  • Wireless medical sensor network
  • Restaurant recommendation apps (for healthy diets)
  • (Smart phones) Apps for outdoor exercise or fitness
  • Wireless medical sensor network
  • Robots (or drones)
  • Wireless medical sensor network
PerformanceBalanced with cost effectiveness
  • As high as possible
  • Not critical
Critical
Cost EffectivenessBalanced with performance
  • As high as possible
  • Not critical
Rigorously examined
Table 2. TFNs for expressing linguistic terms *.
Table 2. TFNs for expressing linguistic terms *.
Linguistic TermTFN
As equal as(1, 1, 3)
As equal as or weakly more important than(1, 2, 4)
Weakly more important than(1, 3, 5)
Weakly or strongly more important than(2, 4, 6)
Strongly more important than(3, 5, 7)
Strongly or very strongly more important than(4, 6, 8)
Very strongly more important than(5, 7, 9)
Very strongly or absolutely more important than(6, 8, 9)
Absolutely more important than(7, 9, 9)
*: Adapted/Reprinted from [57].
Table 3. Pairwise comparison results.
Table 3. Pairwise comparison results.
Critical Factor IRelative PriorityCritical Factor II
Value-added servicesAs equal as or weakly more important thanCost effectiveness
Healthy mobilityWeakly or strongly more important thanValue-added services
Value-added servicesWeakly more important thanNecessity or irreplaceability
Value-added servicesWeakly more important thanCombinability with other smart technology applications
Value-added servicesStrongly more important thanEase of implementation and maintenance
Healthy mobilityStrongly more important thanCost effectiveness
Cost effectivenessWeakly or strongly more important thanNecessity or irreplaceability
Cost effectivenessStrongly more important thanCombinability with other smart technology applications
Cost effectivenessWeakly or strongly more important thanEase of implementation and maintenance
Healthy mobilityStrongly more important thanNecessity or irreplaceability
Healthy mobilityStrongly more important thanCombinability with other smart technology applications
Healthy mobilityStrongly more important thanEase of implementation and maintenance
Necessity or irreplaceabilityStrongly more important thanCombinability with other smart technology applications
Necessity or irreplaceabilityStrongly more important thanEase of implementation and maintenance
Ease of implementation and maintenanceAs equal as or weakly more important thanCombinability with other smart technology applications
Table 4. Potential smart technology applications for supporting mobile healthcare after the COVID-19 pandemic.
Table 4. Potential smart technology applications for supporting mobile healthcare after the COVID-19 pandemic.
qSmart Technology ApplicationSource
1Vaccine passport and related appsHall and Studdert [27], Wu et al. [46]
2Sterilization robotNichols [14]
3Smart bracelet (for monitoring body temperature and blood oxygen level)Ennafiri and Mazri [20], Suhartina and Abuzairi [48]
4Smart watch (for monitoring body temperature, blood oxygen level, heart rate, sleep duration, gesture, motion, step count, and movement).Mishra et al. [50], Zhu et al. [27], Niela-Vilén et al. [52]
5Social distance monitorBian et al. [15]
6Remote temperature scannerInn [50], Tipton and Mekjavic [55]
7Wireless medical sensor networkAli et al. [26]
8Healthcare robot (for monitoring patient’s physiological conditions, supporting surgery, dispensing medication, assisting patients with cognition challenges and disabilities, etc.)Kaiser et al. [62]
9Contact tracing appAbbas and Michael [63]
Table 5. Criteria for evaluating the performance of a smart technology application.
Table 5. Criteria for evaluating the performance of a smart technology application.
Critical FeatureCriterion
Value-added services p ˜ q 1 ( x q 1 ) = { ( 0 , 0 , 1 ) if x q 1 = Very   Low   Value-added   or   data   not   available ( 0 , 1 , 2 ) if x q 1 = Low   Value-added ( 1.5 , 2.5 , 3.5 ) if x q 1 = Moderately   Value-added ( 3 , 4 , 5 ) if x q 1 = High   Value-added ( 4 , 5 , 5 ) if x q 1 = Very   High   Value-added
where x q 1 is the services provided by the q-th smart technology application.
Cost effectiveness p ˜ q 1 ( x q 1 ) = { ( 0 , 0 , 1 ) if 0.1 min r x r 2 + 0.9 max r x r 2 x q 2   or   data   not   available ( 0 , 1 , 2 ) if 0.35 min r x r 2 + 0.65 max r x r 2 x q 2 < 0.1 min r x r 2 + 0.9 max r x r 2 ( 1.5 , 2.5 , 3.5 ) if 0.65 min r x r 2 + 0.35 max r x r 2 x q 2 < 0.35 min r x r 2 + 0.65 max r x r 2 ( 3 , 4 , 5 ) if 0.9 min r x r 2 + 0.1 max r x r 2 x q 2 < 0.65 min r x r 2 + 0.35 max r x r 2 ( 4 , 5 , 5 ) if x q 2 < 0.9 min r x r 2 + 0.1 max r x r 2
where x q 2 is the total costs of the q-th smart technology application.
Healthy mobility p ˜ q 3 ( x q 3 ) = { ( 0 , 0 , 1 ) if x q 3 = Very   Low   or   data   not   available ( 0 , 1 , 2 ) if x q 3 = Low ( 1.5 , 2.5 , 3.5 ) if x q 3 = Moderate ( 3 , 4 , 5 ) if x q 3 = High ( 4 , 5 , 5 ) if x q 3 = Very High
where x q 3 is the degree to which healthy mobility can be improved by the q-th smart technology application.
Necessity or irreplaceability p ˜ q 4 ( x q 4 ) = { ( 0 , 0 , 1 ) if x q 4 = Very   Low   or   data   not   available ( 0 , 1 , 2 ) if x q 4 = Low ( 1.5 , 2.5 , 3.5 ) if x q 4 = Moderate ( 3 , 4 , 5 ) if x q 4 = High ( 4 , 5 , 5 ) if x q 4 = Very High
where x q 4 is the necessity or irreplaceability of the q-th smart technology application.
Combinability with other smart technology applications p ˜ q 5 ( x q 5 ) = { ( 0 , 0 , 1 ) if x q 5 = Very   Low   or   data   not   available ( 0 , 1 , 2 ) if x q 5 = Low ( 1.5 , 2.5 , 3.5 ) if x q 5 = Moderate ( 3 , 4 , 5 ) if x q 5 = High ( 4 , 5 , 5 ) if x q 5 = Very High
where x q 5 is the combinability of the q-th smart technology application with other smart technology applications.
Ease of implementation and maintenance p ˜ q 6 ( x q 6 ) = { ( 0 , 0 , 1 ) if x q 6 = Very   Easy   or   data   not   available ( 0 , 1 , 2 ) if x q 6 = Easy ( 1.5 , 2.5 , 3.5 ) if x q 6 = Moderate ( 3 , 4 , 5 ) if x q 6 = Difficult ( 4 , 5 , 5 ) if x q 6 = Very Difficult
where x q 6 is the ease of implementation and maintenance of the q-th smart technology application.
Table 6. Performances of smart technology applications.
Table 6. Performances of smart technology applications.
q p ˜ q 1 p ˜ q 2 p ˜ q 3 p ˜ q 4 p ˜ q 5 p ˜ q 6
1(3, 4, 5)(1.5, 2.5, 3.5)(4, 5, 5)(3, 4, 5)(1.5, 2.5, 3.5)(1.5, 2.5, 3.5)
2(1.5, 2.5, 3.5)(0, 0, 1)(1.5, 2.5, 3.5)(1.5, 2.5, 3.5)(3, 4, 5)(1.5, 2.5, 3.5)
3(1.5, 2.5, 3.5)(1.5, 2.5, 3.5)(3, 4, 5)(1.5, 2.5, 3.5)(1.5, 2.5, 3.5)(3, 4, 5)
4(3, 4, 5)(1.5, 2.5, 3.5)(3, 4, 5)(1.5, 2.5, 3.5)(3, 4, 5)(1.5, 2.5, 3.5)
5(0, 1, 2)(3, 4, 5)(1.5, 2.5, 3.5)(1.5, 2.5, 3.5)(3, 4, 5)(3, 4, 5)
6(0, 1, 2)(1.5, 2.5, 3.5)(1.5, 2.5, 3.5)(0, 1, 2)(0, 1, 2)(4, 5, 5)
7(4, 5, 5)(0, 1, 2)(3, 4, 5)(1.5, 2.5, 3.5)(1.5, 2.5, 3.5)(0, 1, 2)
8(1.5, 2.5, 3.5)(0, 0, 1)(3, 4, 5)(0, 1, 2)(1.5, 2.5, 3.5)(1.5, 2.5, 3.5)
9(3, 4, 5)(1.5, 2.5, 3.5)(3, 4, 5)(0, 1, 2)(1.5, 2.5, 3.5)(3, 4, 5)
Table 7. Overall performances of smart technology applications.
Table 7. Overall performances of smart technology applications.
q C ˜ q Defuzzified ValueRank
1(0, 0.76, 1)0.5871
2(0, 0.21, 1)0.4049
3(0, 0.55, 1)0.5174
4(0, 0.63, 1)0.5442
5(0, 0.44, 1)0.4816
6(0, 0.31, 1)0.4388
7(0, 0.54, 1)0.5145
8(0, 0.35, 1)0.4497
9(0, 0.59, 1)0.5293
Table 8. Overall performances of smart technology applications evaluated using FGM-FWA.
Table 8. Overall performances of smart technology applications evaluated using FGM-FWA.
qOverall PerformanceDefuzzified ValueRank
1(2.37, 4.06, 4.87)3.761
2(0.88, 2.14, 3.47)2.168
3(1.8, 3.23, 4.64)3.234
4(2, 3.52, 4.82)3.452
5(1.01, 2.58, 4.25)2.616, 7
6(0.54, 2.1, 3.45)2.039
7(1.39, 3.34, 4.65)3.135
8(0.98, 2.58, 4.26)2.616, 7
9(1.67, 3.38, 4.77)3.273
Table 9. Ranking results using FEA-FWA.
Table 9. Ranking results using FEA-FWA.
qOverall PerformanceDefuzzified ValueRank
1(3.04, 4.04, 4.66)3.911
2(1.16, 1.94, 2.94)2.018
3(2.07, 3.07, 4.07)3.075
4(2.4, 3.4, 4.4)3.402
5(1.5, 2.5, 3.5)2.506
6(0.91, 1.91, 2.91)1.919
7(2.29, 3.29, 4.07)3.223
8(1.47, 2.25, 3.25)2.327
9(2.15, 3.15, 4.15)3.154
Table 10. Five smart technology applications were selected using various methods.
Table 10. Five smart technology applications were selected using various methods.
MethodChoices
Fuzzy geometric mean (FGM)-Fuzzy weighted average (FWA)● Vaccine passport and related applications
● Smart watch
● Contact tracing app
● Smart bracelet
● Wireless medical sensor network
Fuzzy extent analysis (FEA)-Fuzzy weighted average (FWA)● Vaccine passport and related applications
● Smart watch
● Wireless medical sensor network
● Contact tracing app
● Smart bracelet
The proposed methodology● Vaccine passport and related application
● Smart watches
● Contact tracing app
● Smart bracelet
● Wireless medical sensor network
Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Share and Cite

MDPI and ACS Style

Chen, T.; Wang, Y.-C. Recommending Suitable Smart Technology Applications to Support Mobile Healthcare after the COVID-19 Pandemic Using a Fuzzy Approach. Healthcare 2021, 9, 1461. https://doi.org/10.3390/healthcare9111461

AMA Style

Chen T, Wang Y-C. Recommending Suitable Smart Technology Applications to Support Mobile Healthcare after the COVID-19 Pandemic Using a Fuzzy Approach. Healthcare. 2021; 9(11):1461. https://doi.org/10.3390/healthcare9111461

Chicago/Turabian Style

Chen, Toly, and Yu-Cheng Wang. 2021. "Recommending Suitable Smart Technology Applications to Support Mobile Healthcare after the COVID-19 Pandemic Using a Fuzzy Approach" Healthcare 9, no. 11: 1461. https://doi.org/10.3390/healthcare9111461