Development of Indoor Air Quality Measuring Device and Application to Support Campus in Post-Covid-19 Pandemic Class Preparation

Authors

  • Hendra Jatnika Informatics Engineering, Faculty of Telematics Energy, Institut Teknologi PLN
  • Mochamad Farid Rifai Informatics Engineering, Faculty of Telematics Energy, Institut Teknologi PLN, Indonesia
  • Yudhi S. Purwanto Informatics Engineering, Faculty of Telematics Energy, Institut Teknologi PLN, Indonesia1

DOI:

https://doi.org/10.46799/ijssr.v3i10.572

Keywords:

Development, campus classrooms, geolocation tagging, indoor air quality, measuring device, Covid-19

Abstract

The Covid-19 pandemic has left our campus classrooms empty for a long time. The main concern of this research is to ensure the cleanliness of the classroom, not only for the materials and the room, but also for the air in it. Clean and safe indoor air is determined by several factors, one of which is air ventilation. Standard classrooms usually need to have plenty of ventilation to ensure airflow, but in general, in most large cities, the case is not that simple. Some schools have a narrow area, some are in dense rural areas or in industrial areas, some use air conditioning but lack maintenance, etc. This research focuses on the development of indoor air quality measuring device that can be used to check the air quality of classrooms and transmit the results to parents and other related parties. The device is made using a wi-fi integrated microcontroller module which is equipped with sensors measuring air conditions. It is also connected to the application on the android phone, and the data is stored on the web. It is also embedded with geolocation tagging to indicate the exact location of activity. The stored data can be used as basic data to make predictions about air quality conditions in a particular place in the future.

References

Akanmu, W.P., Nunayon, S.S. and Eboson, U.C. (2021) ‘Indoor environmental quality (IEQ) assessment of Nigerian university libraries: A pilot study’, Energy and Built Environment, 2(3), pp. 302–314. Available at: https://doi.org/10.1016/j.enbenv.2020.07.004.

Annie Hoang, A.H. (2021) ‘Preparation in the Pandemic?: How Schools Implemented Air Quality Measures to Protect Occupants from’, Ashrae [Preprint].

ASHRAE (2020) ‘Guidance for the Re-Opening of Schools’, (August, 2020), p. 55.

Chojer, H. et al. (2020) ‘Development of low-cost indoor air quality monitoring devices: Recent advancements’, Science of The Total Environment, 727, p. 138385. Available at: https://doi.org/10.1016/j.scitotenv.2020.138385.

Elkhwesky, Z. et al. (2022) ‘Sustainable practices in hospitality pre and amid COVID?19 pandemic: Looking back for moving forward post?COVID?19’, Sustainable Development, 30(5), pp. 1426–1448. Available at: https://doi.org/10.1002/sd.2304.

Faroqi, A. et al. (2016) ‘Perancangan Alat Pendeteksi Kadar Polusi Udara Menggunakan Sensor Gas MQ-7 Dengan Teknologi Wirelles HC-05’, Jurnal ISTEK, X(2), pp. 33–47.

Habibi, S. (2016) ‘Smart innovation systems for indoor environmental quality (IEQ)’, Journal of building engineering, 8, pp. 1–13. Available at: https://doi.org/10.1016/j.jobe.2016.08.006.

Holubar, T. (2021) Indoor air quality receives more focus in pandemic era, CNHI News Oklahoma.

Khan, D.S., Kolarik, J. and Weitzmann, P. (2020) ‘Design and application of occupant voting systems for collecting occupant feedback on indoor environmental quality of buildings–a review’, Building and Environment, 183, p. 107192. Available at: https://doi.org/10.1016/j.buildenv.2020.107192.

Mandayo, G.G. et al. (2015) ‘System to control indoor air quality in energy efficient buildings’, Urban Climate, 14, pp. 475–485. Available at: https://doi.org/10.1016/j.uclim.2014.10.009.

Morawska, L. et al. (2018) ‘Applications of low-cost sensing technologies for air quality monitoring and exposure assessment: How far have they gone?’, Environment international, 116, pp. 286–299. Available at: https://doi.org/10.1016/j.envint.2018.04.018.

Nur Arminarahmah, Muhammad Rasyidan and Zaenuddin (2017) ‘Desain Dan Implementasi Pengukur Kualitas Udara Pm10 Berbasis Mikrokontroller’, Jurnal Teknologi Informasi Universitas Lambung Mangkurat (JTIULM), 2(1), pp. 21–28. Available at: https://doi.org/10.20527/jtiulm.v2i1.15.

Perera, M. and Jayasinghe, C. (2012) ‘Indoor Air quality and human activities in buildings Civil Engineering Research Exchange Symposium 2012 Faculty of Engineering University of Ruhuna’, (January 2016), pp. 1–8. Available at: https://doi.org/10.13140/RG.2.1.2124.2961.

Rosmiati, M. et al. (2019) ‘Air pollution monitoring system using LoRa modul as transceiver system’, Telkomnika (Telecommunication Computing Electronics and Control), 17(2), pp. 586–592. Available at: https://doi.org/10.12928/TELKOMNIKA.V17I2.11760.

Sa, J.P. et al. (2022) ‘Application of the low-cost sensing technology for indoor air quality monitoring: A review’, Environmental Technology & Innovation, 28, p. 102551. Available at: https://doi.org/https://doi.org/10.1016/j.eti.2022.102551.

Saha, S., Guha, A. and Roy, S. (2012) ‘Experimental and computational investigation of indoor air quality inside several community kitchens in a large campus’, Building and Environment, 52, pp. 177–190. Available at: https://doi.org/10.1016/j.buildenv.2011.10.015.

Sai, K.B.K., Ramasubbareddy, S. and Luhach, A.K. (2019) ‘IOT based air quality monitoring system using MQ135 and MQ7 with machine learning analysis’, Scalable Computing, 20(4), pp. 599–606. Available at: https://doi.org/10.12694/scpe.v20i4.1561.

Sebayang, M.A. (2017) ‘Journal of Informatics and Telecommunication Engineering Stasiun Pemantau Kualitas Udara Berbasis Web Web Based Quality Air Monitor Station melakukan perancangan alat , perancangan melakukan MQ-7 Sensor MQ-7 tersusun oleh tabung’, Journal of Informatics and Telecommunication and Engineering (JITE), 1(1), pp. 24–33.

Sharifi, A. and Khavarian-Garmsir, A.R. (2020) ‘The COVID-19 pandemic: Impacts on cities and major lessons for urban planning, design, and management’, Science of the total environment, 749, p. 142391. Available at: https://doi.org/10.1016/j.scitotenv.2020.142391.

Sharma, P.K. et al. (2021) ‘IndoAirSense: A framework for indoor air quality estimation and forecasting’, Atmospheric Pollution Research, 12(1), pp. 10–22. Available at: https://doi.org/10.1016/j.apr.2020.07.027.

Sugiarso, B.A. et al. (2019) ‘Aplikasi Sensor Polusi Udara’, Jurnal Teknik Elektro dan Komputer, 8(3), pp. 193–200.

Vidyautami, D.N. (Devi), Huboyo, H.S. (Haryono) and Hadiwidodo, M. (Mochtar) (2015) ‘Pengaruh Penggunaan Ventilasi (Ac Dan Non Ac) Dalam Ruangan Terhadap Keberadaan Mikroorganisme Udara (Studi Kasus?: Ruang Kuliah Jurusan Teknik Sipil Universitas Diponegoro)’, Jurnal Teknik Lingkungan, 4(1), pp. 1–8.

Waworundeng, J. and Lengkong, O. (2018) ‘Sistem Monitoring dan Notifikasi Kualitas Udara dalam Ruangan dengan Platform IoT Indoor Air Quality Monitoring and Notification System with IoT Platform’, Cogito Smart Journal, 4(1), pp. 94–102.

Waworundeng, J.M.S. (2017) ‘Implementasi Sensor dan Mikrokontroler sebagai Detektor Kualitas Udara’, Seminar Nasional Multi Disiplin Ilmu, 1(November 2017), pp. 232–240.

World Health Organization (2020) ‘Checklist to support schools re-opening and preparation for COVID-19 resurgences or similar public health crises’, Who, pp. 1–20.

Zikri, M. and Khair, R. (2018) ‘Rancang Bangun Monitoring Polusi Udara Berbasis Arduino’, Jurnal Teknovasi, 05(01), pp. 27–38.