Introduction

After the spread of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), anesthesia practice has dramatically changed. Medical providers should take care to protect themselves from coronavirus disease 2019 (COVID-19) from infected individuals and to spread COVID-19 to someone else. Findings for the transmission of SARS-CoV-2 would help to reduce future transmission in hospitals. For infection control, laboratory tests such as reverse transcription polymerase chain reaction (RT-PCR) test or rapid antigen test may be used for screening before surgeries. Many anesthesiologists may not be familiar with the interpretation of the results of laboratory tests and the meaning of sensitivity and specificity of laboratory tests. Several examples have been presented for those understandings here.

Consideration for transmission and its prevention of SARS-CoV-2

Many publications have described the super-spreading of SARS-CoV-2 by choir practice [1], by an asymptomatic traveler possibly via polluted air in the elevator [2], at health-care facilities, and related to deep breathing in close contact such as singing at karaoke parties, cheering at clubs, having conversations in bars, and exercising in gymnasiums [3]. Based on these reports, aerosol can be considered as a primary transmission route.

One study has shown the stability of SARS-CoV-2 in aerosol and on surface compared with that of SARS-CoV-1 under the experimental condition at 21–23 °C, 40% relative humidity [4]. On plastic and stainless steel and in aerosol, the estimated median half-lives of SARS-CoV-2 were 6.8, 5.6, and 1.1 h, which were similar to that of SARS-CoV-1. The results indicate that the difference in transmission characteristics depends on other factors. Possible causes of SARS-CoV-2 spreading rapidly are a higher discharge ratio from infected people and viral kinetics in the human body including a higher viral intake ratio to the human body. Concerning the viral kinetics, there is an important basic research showing that the infectivity of SARS-CoV-2 in the nose was higher than that in the peripheral lung [5]. The article recommends the widespread use of masks to prevent aerosol, large droplet, and/or mechanical exposure to the nasal passages. Although universal masking had doubtful preventive effect against viral infection until early in 2020, which may be due to the small virus size (approximately 120 nm in diameter), one experiment supports the effectiveness of surgical mask [6]. A perspective has discussed the importance and benefit of universal masking [7]. Another unpeer-reviewed archive has suggested that COVID-19 can spread from 1 to 10% of infected individuals, resulting in 80% of secondary infections with an analysis for 212 sequential SARS-CoV-2 infections [8]. The possibility of transmission from presymptomatic and asymptomatic SARS-CoV-2 infected patients, and the possibility of peak infectiousness at 2 days before to 1 day after onset from the infector–infectee paired data have been shown [9, 10]. These publications confirmed that prevention is a principal factor to control the spread of the SARS-CoV-2 infection.

Laboratory tests for SAR-CoV2 infection and their interpretation

A good review article has been published about various laboratory tests for SARS-CoV-2 and has stated the advantages and disadvantages of the tests [11]. The most global test is an RT-PCR test, which could have a high analytical sensitivity of 95% [12]. Note that this sensitivity is NOT the sensitivity of laboratory test. In the laboratory test in an infected patient, the sample such as nasopharyngeal swab may have no SARS-CoV-2. This patient has reduced sensitivity for the laboratory test. The RT-PCR test for SARS-CoV-2 is likely to have high specificity, but moderate sensitivity [13].

Other serology-based laboratory tests are also available to detect SARS-CoV-2 infection such as enzyme-linked immunosorbent assays (ELISA) for Ig A, IgM, or IgG. The positive rate of these tests in patients with SARS-CoV-2 infection may be influenced by the duration after the onset of the infection [11, 14]. This is a disadvantage of the test. However, an article has shown that the detection ratio of IgM ELISA for SARS-CoV-2 was higher than that of RT-PCR after 5.5 days or later of the symptom onset [14]. Additionally, the combination of RT-PCR and IgM ELISA improved the detection rate [14]. Rapid antigen testing is available, but its sensitivity is moderate and is currently lower than that of RT-PCR test [15]. As the conditions of these laboratory tests improves every day, the latest information would be found and considered in the next few years.

When a test for SARS-CoV-2 such as RT-PCR test is used before scheduled surgeries, anesthesiologists should understand the meaning of ‘positive’ and ‘negative’ results of the test. To understand the result of a laboratory test, positive predictive value (PPV) and negative predictive value (NPV) are useful. PPV indicates the ratio of true-positive patients among all test-positive patients, and NPV indicates the ratio of true-negative patients among all test-negative patients. (Table 1) However, PPV and NPV are not applicable without the infection probability of the patient or infection ratio in the population. Instead, sensitivity and specificity are applied for a laboratory test. (Table 1) These indices describe “the ability of the test”, but not “the ratio of infected patients versus the result of the test.”

Table 1 Positive and negative predictive values for laboratory test

Here, various examples show the PPV and NPV calculated using sensitivity, specificity, and probability of infection for RT-PCR test (Table 2). For the calculations, the total number of the population is set at 1000. Examples 1–1 to 1–7 show the PPV and NPV values for sensitivity of 70%, specificity of 95% [13], and infection probability between 1 and 80%. When the infection probability is 1% (Ex 1–1 in Table 2), PPV is only 12.4% and NPV is 99.7%. This means that 87.6% (this is the false discovery rate: FDR) of all test-positive patients are not infected, while 0.3% (this is the false omission rate: FOR) of all test-negative patients are infected. In this case, the tested patient should be considered to have infection probability of 1% before the test. Another example is with the infection probability of 80% (Ex 1–7 in Table 2), PPV of 98.2% and NPV of 44.2%. This means that 1.8% of all test-positive patients are not infected, while 55.8% of all test-negative patients are infected. The results suggest that one should not be confident only with a result of a laboratory testing and that symptoms and other findings are also important for the diagnosis of SARS-CoV-2 infection. The influence of sensitivity on PPV and NPV can be studied on comparing the Ex 1, 2, and 3. The sensitivity range 70–90% influences NPV especially for high infection probability, but influences PPV little. The influence of specificity on PPV and NPV can be inspected when comparing Ex 1, 4, and 5, or Ex 3, 5, and 7. The specificity range 95–99% has a large impact on PPV for lower infection probability, e.g., a change in specificity from 95 to 99% with sensitivity of 70% increases PPV from 12.4% to 41.4% on infection probability of 1% (Ex 1–1 versus Ex 6–1) or PPV from 42.4% to 88.6% on infection probability of 10% (Ex 1–3 versus Ex 6–3). A change in specificity between these ranges has little impact on NPV.

Table 2 Examples of positive and negative predictive value for RT-PCR test in patients with suspected SARS-CoV-2 infection

All laboratory tests are not perfect. The “infected patient” can have a “negative” result of the test (this is “false negative”) similar to an “infected patient” being “asymptomatic.” But, is laboratory test useless? The answer is “NO.” For the special population, laboratory test would be useful. When the infection probability is ≤ 5% in a patient with sensitivity > 70% and specificity > 95% of the laboratory test, NPV results in > 98%. In other words, the negative result of the test means uninfected in > 98% patients. In contrast, when the infection probability is ≥ 40% in a patient, with sensitivity of 70% and specificity > 95% of the laboratory test, NPV results in < 83.3%. This means that 16.7% in the “negative” population, i.e., one out of six people, is infected. For PPV, when the infection probability is 1% in a patient with sensitivity between 70 and 90% and specificity of 95% of the laboratory test, PPV results in < 16.7%. This means that five “uninfected” out of six people have a “positive” result of the test (“false positive”). If you are interested in calculating PPV and NPV by yourself, you can find a good calculator in a website of an article [13]. Please realize that the PPV and NPV depend on not only sensitivity and specificity of the laboratory test, but also the infection probability of the patient.